Hacker Newsnew | past | comments | ask | show | jobs | submitlogin

I've got a counter-flow heat exchanger, but it looks like they're using a different design:

> Each OpenERV TW4 module has a very quiet pair of fans, pointed in opposite directions, and a heat exchanger in a 6 inch pipe, that goes through a wall. The hot, polluted air from inside goes out for 30 seconds, and the heat from it is stored in the heat exchanger.

> Then, the fan reverses direction, moving clean air from outdoors to the indoors. On it's way in, it picks up that heat from the heat exchanger. This type of heat exchanger is called a regenerative heat exchanger, or less commonly, a regenerator. The kind shown in the video is a recuperative type, not regenerative. Recuperative types are what most people think of, consisting of a thin layer of material that separates two gas streams. Regenerative heat exchangers are different. They briefly store the energy while air flows in one direction, then release it when the air flow reverses.

> The OpenERV TW4 modules are made to always work in pairs. One always sucks air while the other blows air, synchronized over WiFi. This should be done, or hot air would be pushed out from the building through the walls during the ingress phase, causing heat loss.

https://www.openerv.ca/learn-more



Guidelines | FAQ | Lists | API | Security | Legal | Apply to YC | Contact

Search: